• O1 Network
    • Articles
    • For Residents
    • For Medical Students
    • PORT Notes
    • MSK Medicine
    • Tumor Library
    • Cases
    • Talks
    • Images
    • Viewpoints
    • Question Bank
    • Devices
    • Residency
    • Fellowships
    • Associations
    • Companies
ORTHOPAEDICSONE ARTICLES
OrthopaedicsOne Articles
  • Articles
    • Specialty
      • Arthroscopy
      • Foot and Ankle
      • Hand and Wrist
      • Hip and Knee
      • Infection
      • Joint Reconstruction
      • Musculoskeletal Medicine
      • Pediatrics
      • Shoulder and Elbow
      • Spine
      • Sports Medicine
      • Trauma
      • Tumor
    • Regional
      • Anatomy
      • Basic Science
      • Classifications
      • Diagnostic Tests
      • Evidence-Based Orthopaedics
      • Operative Techniques
      • Pain Management
      • Physical Examination
      • Pharmacology
      • Radiology
      • Rehabilitation
      • Rheumatology
      • Surgical Approaches
    • Professional
      • Bioethics
      • Economics and Health Policy
      • Epidemiology and Biostatistics
      • History of Orthopaedics
      • Informatics
      • Medicolegal
      • Mobile and Wireless
      • Practice Management
  • Reviews
    • For Residents
    • For Medical Students
  • eBooks
    • PORT Notes
    • MSK Medicine
    • Tumor Library
  • Community
    • Cases
    • Talks
    • Images
    • Viewpoints
    • Question Bank
    • Devices
  • Pages
    • Residency
    • Fellowships
    • Associations
    • Companies
  • About O1
    • Overview
    • FAQs
    • Managing Editors
    • Editorial Board
    • Content Partners
    • Participating Groups
    • Advisory Board
    • Sponsoring Organizations
    • Contact Us
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu

Cobalt and Chromium Concentrations in Patients with Metal on Metal Total Hip Replacements

Abstract

There has been a resurgence of interest in the use of metal on metal bearings in total hip arthroplasty. Although the use of metal on metal bearing couples would eliminate or substantially reduce particulate polyethylene generation (depending on the presence or absence of polyethylene in the implant system), there is concern about the potential for increased particulate and ionic metal generation in comparison with polyethylene on metal bearings. These metallic degradation products may be transported away from the implant site and distributed systemically. Chromium concentrations in the serum and urine and cobalt concentrations in the serum were measured in subjects with cobalt chromium alloy metal on metal total hip replacements and in controls without implants. Eight subjects with long term (> 20 years) McKee-Farrar total hip replacements had 9-fold elevations in serum chromium, 35-fold elevations in urine chromium, and at least 3-fold elevations in serum cobalt concentrations in comparison with controls. Six subjects with short term (< 2 years) metal on metal surface replacement arthroplasties had 3-fold elevations in serum chromium, 4-fold elevations in urine chromium, and 4-fold elevations in serum cobalt concentrations in comparison with subjects with McKee-Farrar implants. Although the toxicologic importance of these trace metal elevations has not been established, serum and urine metal concentrations may be useful markers for the tribologic performance of metal on metal bearings.

Full-text article

Last Updated on June 27, 2024

🔗 Knowledge Graph & Clinical Correlates

OrthopaedicsOne Living Semantic Network

🛠️ Operative Techniques

  • Valgus osteotomy for Perthes disease Pediatrics
  • Valgus osteotomy for development coxa vara Hip and Knee

🩺 Clinical Conditions & Indications

  • Which EMR should I choose Original Clinical Contribution: Authored for the OrthopaedicsOne General Orthopaedics Specialty Section. Preserved, digitized, and updated to modern evidence-based...

🔬 Anatomy, Pathology & Diagnostics

  • Why I Would Not Consider Navigating My THA Hip Joint & Proximal Femur
  • Why I Would Consider Navigating My THA Hip Joint & Proximal Femur
  • Why I Use Metal on Metal Hip Joint & Proximal Femur
  • Why I Use Cross-Linked Polyethylene Hip Joint & Proximal Femur

🕸️ Semantic Relations (RDF)

ABOUT

  • Overview
  • FAQs
  • Managing Editors
  • Editorial Board
  • Content Partners
  • Participating Groups
  • Advisory Board
  • Sponsoring Organizations
  • Contact Us

ARTICLES

  • Arthroscopy
  • Foot and Ankle
  • Hand and Wrist
  • Hip and Knee
  • Infection
  • Joint Reconstruction
  • Musculoskeletal Medicine
  • Pediatrics
  • Shoulder and Elbow
  • Spine
  • Sports Medicine
  • Trauma
  • Tumor

REVIEWS

  • For Residents
  • For Medical Students

EBOOKS

  • PORT Notes
  • MSK Medicine
  • Tumor Library

COMMUNITY

  • Talks
  • Images
  • Viewpoints
  • Question Bank
  • Devices

PAGES

  • Residency
  • Fellowships
  • Associations
  • Companies
Copyright © 2012-2026 OrthopaedicsOne | Privacy Policy | Dr. Christian Veillette . Powered by: OrthoNet - Empowering the Future of Orthopaedic Care
Scroll to top Scroll to top Scroll to top